diff options
| author | Linus Torvalds <torvalds@linux-foundation.org> | 2020-04-02 17:03:53 -0700 |
|---|---|---|
| committer | Linus Torvalds <torvalds@linux-foundation.org> | 2020-04-02 17:03:53 -0700 |
| commit | 79f51b7b9c4719303f758ae8406c4e5997ed6aa3 (patch) | |
| tree | 33ca1c3ee11848e75d90f811038fcd149e69d258 /Documentation/scsi | |
| parent | e109f506074152b7241bcbd3949a099e776cb802 (diff) | |
| parent | ff275db92c935858454b721f0d960fff421634d3 (diff) | |
| download | linux-79f51b7b9c4719303f758ae8406c4e5997ed6aa3.tar.gz linux-79f51b7b9c4719303f758ae8406c4e5997ed6aa3.tar.bz2 linux-79f51b7b9c4719303f758ae8406c4e5997ed6aa3.zip | |
Merge tag 'scsi-misc' of git://git.kernel.org/pub/scm/linux/kernel/git/jejb/scsi
Pull SCSI updates from James Bottomley:
"This series has a huge amount of churn because it pulls in Mauro's doc
update changing all our txt files to rst ones.
Excluding that, we have the usual driver updates (qla2xxx, ufs, lpfc,
zfcp, ibmvfc, pm80xx, aacraid), a treewide update for scnprintf and
some other minor updates.
The major core change is Hannes moving functions out of the aacraid
driver and into the core"
* tag 'scsi-misc' of git://git.kernel.org/pub/scm/linux/kernel/git/jejb/scsi: (223 commits)
scsi: aic7xxx: aic97xx: Remove FreeBSD-specific code
scsi: ufs: Do not rely on prefetched data
scsi: dc395x: remove dc395x_bios_param
scsi: libiscsi: Fix error count for active session
scsi: hpsa: correct race condition in offload enabled
scsi: message: fusion: Replace zero-length array with flexible-array member
scsi: qedi: Add PCI shutdown handler support
scsi: qedi: Add MFW error recovery process
scsi: ufs: Enable block layer runtime PM for well-known logical units
scsi: ufs-qcom: Override devfreq parameters
scsi: ufshcd: Let vendor override devfreq parameters
scsi: ufshcd: Update the set frequency to devfreq
scsi: ufs: Resume ufs host before accessing ufs device
scsi: ufs-mediatek: customize the delay for enabling host
scsi: ufs: make HCE polling more compact to improve initialization latency
scsi: ufs: allow custom delay prior to host enabling
scsi: ufs-mediatek: use common delay function
scsi: ufs: introduce common and flexible delay function
scsi: ufs: use an enum for host capabilities
scsi: ufs: fix uninitialized tx_lanes in ufshcd_disable_tx_lcc()
...
Diffstat (limited to 'Documentation/scsi')
| -rw-r--r-- | Documentation/scsi/53c700.rst (renamed from Documentation/scsi/53c700.txt) | 61 | ||||
| -rw-r--r-- | Documentation/scsi/BusLogic.rst (renamed from Documentation/scsi/BusLogic.txt) | 89 | ||||
| -rw-r--r-- | Documentation/scsi/FlashPoint.rst | 176 | ||||
| -rw-r--r-- | Documentation/scsi/FlashPoint.txt | 163 | ||||
| -rw-r--r-- | Documentation/scsi/NinjaSCSI.rst | 164 | ||||
| -rw-r--r-- | Documentation/scsi/NinjaSCSI.txt | 128 | ||||
| -rw-r--r-- | Documentation/scsi/aacraid.rst (renamed from Documentation/scsi/aacraid.txt) | 59 | ||||
| -rw-r--r-- | Documentation/scsi/advansys.rst (renamed from Documentation/scsi/advansys.txt) | 129 | ||||
| -rw-r--r-- | Documentation/scsi/aha152x.rst (renamed from Documentation/scsi/aha152x.txt) | 73 | ||||
| -rw-r--r-- | Documentation/scsi/aic79xx.rst | 593 | ||||
| -rw-r--r-- | Documentation/scsi/aic79xx.txt | 497 | ||||
| -rw-r--r-- | Documentation/scsi/aic7xxx.rst | 458 | ||||
| -rw-r--r-- | Documentation/scsi/aic7xxx.txt | 394 | ||||
| -rw-r--r-- | Documentation/scsi/arcmsr_spec.rst | 907 | ||||
| -rw-r--r-- | Documentation/scsi/arcmsr_spec.txt | 574 | ||||
| -rw-r--r-- | Documentation/scsi/bfa.rst (renamed from Documentation/scsi/bfa.txt) | 28 | ||||
| -rw-r--r-- | Documentation/scsi/bnx2fc.rst (renamed from Documentation/scsi/bnx2fc.txt) | 18 | ||||
| -rw-r--r-- | Documentation/scsi/cxgb3i.rst (renamed from Documentation/scsi/cxgb3i.txt) | 22 | ||||
| -rw-r--r-- | Documentation/scsi/dc395x.rst (renamed from Documentation/scsi/dc395x.txt) | 79 | ||||
| -rw-r--r-- | Documentation/scsi/dpti.rst | 92 | ||||
| -rw-r--r-- | Documentation/scsi/dpti.txt | 83 | ||||
| -rw-r--r-- | Documentation/scsi/g_NCR5380.rst | 93 | ||||
| -rw-r--r-- | Documentation/scsi/g_NCR5380.txt | 68 | ||||
| -rw-r--r-- | Documentation/scsi/hpsa.rst (renamed from Documentation/scsi/hpsa.txt) | 79 | ||||
| -rw-r--r-- | Documentation/scsi/hptiop.rst (renamed from Documentation/scsi/hptiop.txt) | 45 | ||||
| -rw-r--r-- | Documentation/scsi/index.rst | 51 | ||||
| -rw-r--r-- | Documentation/scsi/libsas.rst (renamed from Documentation/scsi/libsas.txt) | 352 | ||||
| -rw-r--r-- | Documentation/scsi/link_power_management_policy.rst (renamed from Documentation/scsi/link_power_management_policy.txt) | 12 | ||||
| -rw-r--r-- | Documentation/scsi/lpfc.rst (renamed from Documentation/scsi/lpfc.txt) | 16 | ||||
| -rw-r--r-- | Documentation/scsi/megaraid.rst (renamed from Documentation/scsi/megaraid.txt) | 47 | ||||
| -rw-r--r-- | Documentation/scsi/ncr53c8xx.rst (renamed from Documentation/scsi/ncr53c8xx.txt) | 1871 | ||||
| -rw-r--r-- | Documentation/scsi/ppa.rst | 18 | ||||
| -rw-r--r-- | Documentation/scsi/ppa.txt | 14 | ||||
| -rw-r--r-- | Documentation/scsi/qlogicfas.rst (renamed from Documentation/scsi/qlogicfas.txt) | 17 | ||||
| -rw-r--r-- | Documentation/scsi/scsi-changer.rst (renamed from Documentation/scsi/scsi-changer.txt) | 36 | ||||
| -rw-r--r-- | Documentation/scsi/scsi-generic.rst (renamed from Documentation/scsi/scsi-generic.txt) | 75 | ||||
| -rw-r--r-- | Documentation/scsi/scsi-parameters.rst (renamed from Documentation/scsi/scsi-parameters.txt) | 28 | ||||
| -rw-r--r-- | Documentation/scsi/scsi.rst (renamed from Documentation/scsi/scsi.txt) | 31 | ||||
| -rw-r--r-- | Documentation/scsi/scsi_eh.rst (renamed from Documentation/scsi/scsi_eh.txt) | 213 | ||||
| -rw-r--r-- | Documentation/scsi/scsi_fc_transport.rst (renamed from Documentation/scsi/scsi_fc_transport.txt) | 242 | ||||
| -rw-r--r-- | Documentation/scsi/scsi_mid_low_api.rst | 1313 | ||||
| -rw-r--r-- | Documentation/scsi/scsi_mid_low_api.txt | 1259 | ||||
| -rw-r--r-- | Documentation/scsi/scsi_transport_srp/Makefile | 7 | ||||
| -rw-r--r-- | Documentation/scsi/scsi_transport_srp/figures.rst | 6 | ||||
| -rw-r--r-- | Documentation/scsi/sd-parameters.rst | 27 | ||||
| -rw-r--r-- | Documentation/scsi/sd-parameters.txt | 22 | ||||
| -rw-r--r-- | Documentation/scsi/smartpqi.rst (renamed from Documentation/scsi/smartpqi.txt) | 52 | ||||
| -rw-r--r-- | Documentation/scsi/st.rst (renamed from Documentation/scsi/st.txt) | 301 | ||||
| -rw-r--r-- | Documentation/scsi/sym53c500_cs.rst (renamed from Documentation/scsi/sym53c500_cs.txt) | 8 | ||||
| -rw-r--r-- | Documentation/scsi/sym53c8xx_2.rst (renamed from Documentation/scsi/sym53c8xx_2.txt) | 1131 | ||||
| -rw-r--r-- | Documentation/scsi/tcm_qla2xxx.rst (renamed from Documentation/scsi/tcm_qla2xxx.txt) | 26 | ||||
| -rw-r--r-- | Documentation/scsi/ufs.rst (renamed from Documentation/scsi/ufs.txt) | 84 | ||||
| -rw-r--r-- | Documentation/scsi/wd719x.rst | 24 | ||||
| -rw-r--r-- | Documentation/scsi/wd719x.txt | 21 |
54 files changed, 7049 insertions, 5327 deletions
diff --git a/Documentation/scsi/53c700.txt b/Documentation/scsi/53c700.rst index e31aceb6df15..53a0e9f9c198 100644 --- a/Documentation/scsi/53c700.txt +++ b/Documentation/scsi/53c700.rst @@ -1,3 +1,9 @@ +.. SPDX-License-Identifier: GPL-2.0 + +======================= +The 53c700 Driver Notes +======================= + General Description =================== @@ -16,9 +22,9 @@ fill in to get the driver working. Compile Time Flags ================== -A compile time flag is: +A compile time flag is:: -CONFIG_53C700_LE_ON_BE + CONFIG_53C700_LE_ON_BE define if the chipset must be supported in little endian mode on a big endian architecture (used for the 700 on parisc). @@ -51,9 +57,11 @@ consistent with the best operation of the chip (although some choose to drive it off the CPU or bus clock rather than going to the expense of an extra clock chip). The best operation clock speeds are: -53c700 - 25MHz -53c700-66 - 50MHz -53c710 - 40Mhz +========= ===== +53c700 25MHz +53c700-66 50MHz +53c710 40Mhz +========= ===== Writing Your Glue Driver ======================== @@ -69,7 +77,7 @@ parameters that matter to you (see below), plumb the NCR_700_intr routine into the interrupt line and call NCR_700_detect with the host template and the new parameters as arguments. You should also call the relevant request_*_region function and place the register base -address into the `base' pointer of the host parameters. +address into the 'base' pointer of the host parameters. In the release routine, you must free the NCR_700_Host_Parameters that you allocated, call the corresponding release_*_region and free the @@ -78,7 +86,7 @@ interrupt. Handling Interrupts ------------------- -In general, you should just plumb the card's interrupt line in with +In general, you should just plumb the card's interrupt line in with request_irq(irq, NCR_700_intr, <irq flags>, <driver name>, host); @@ -95,41 +103,32 @@ Settable NCR_700_Host_Parameters The following are a list of the user settable parameters: clock: (MANDATORY) - -Set to the clock speed of the chip in MHz. + Set to the clock speed of the chip in MHz. base: (MANDATORY) - -set to the base of the io or mem region for the register set. On 64 -bit architectures this is only 32 bits wide, so the registers must be -mapped into the low 32 bits of memory. + Set to the base of the io or mem region for the register set. On 64 + bit architectures this is only 32 bits wide, so the registers must be + mapped into the low 32 bits of memory. pci_dev: (OPTIONAL) - -set to the PCI board device. Leave NULL for a non-pci board. This is -used for the pci_alloc_consistent() and pci_map_*() functions. + Set to the PCI board device. Leave NULL for a non-pci board. This is + used for the pci_alloc_consistent() and pci_map_*() functions. dmode_extra: (OPTIONAL, 53c710 only) - -extra flags for the DMODE register. These are used to control bus -output pins on the 710. The settings should be a combination of -DMODE_FC1 and DMODE_FC2. What these pins actually do is entirely up -to the board designer. Usually it is safe to ignore this setting. + Extra flags for the DMODE register. These are used to control bus + output pins on the 710. The settings should be a combination of + DMODE_FC1 and DMODE_FC2. What these pins actually do is entirely up + to the board designer. Usually it is safe to ignore this setting. differential: (OPTIONAL) - -set to 1 if the chip drives a differential bus. + Set to 1 if the chip drives a differential bus. force_le_on_be: (OPTIONAL, only if CONFIG_53C700_LE_ON_BE is set) - -set to 1 if the chip is operating in little endian mode on a big -endian architecture. + Set to 1 if the chip is operating in little endian mode on a big + endian architecture. chip710: (OPTIONAL) - -set to 1 if the chip is a 53c710. + Set to 1 if the chip is a 53c710. burst_disable: (OPTIONAL, 53c710 only) - -disable 8 byte bursting for DMA transfers. - + Disable 8 byte bursting for DMA transfers. diff --git a/Documentation/scsi/BusLogic.txt b/Documentation/scsi/BusLogic.rst index 48e982cd6fe7..b60169812358 100644 --- a/Documentation/scsi/BusLogic.txt +++ b/Documentation/scsi/BusLogic.rst @@ -1,6 +1,11 @@ - BusLogic MultiMaster and FlashPoint SCSI Driver for Linux +.. SPDX-License-Identifier: GPL-2.0 + +========================================================= +BusLogic MultiMaster and FlashPoint SCSI Driver for Linux +========================================================= Version 2.0.15 for Linux 2.0 + Version 2.1.15 for Linux 2.1 PRODUCTION RELEASE @@ -8,13 +13,16 @@ 17 August 1998 Leonard N. Zubkoff + Dandelion Digital + lnz@dandelion.com Copyright 1995-1998 by Leonard N. Zubkoff <lnz@dandelion.com> - INTRODUCTION +Introduction +============ BusLogic, Inc. designed and manufactured a variety of high performance SCSI host adapters which share a common programming interface across a diverse @@ -86,9 +94,11 @@ Contact information for offices in Europe and Japan is available on the Web site. - DRIVER FEATURES +Driver Features +=============== -o Configuration Reporting and Testing +Configuration Reporting and Testing +----------------------------------- During system initialization, the driver reports extensively on the host adapter hardware configuration, including the synchronous transfer parameters @@ -130,7 +140,8 @@ o Configuration Reporting and Testing The status of Wide Negotiation, Disconnect/Reconnect, and Tagged Queuing are reported as "Enabled", Disabled", or a sequence of "Y" and "N" letters. -o Performance Features +Performance Features +-------------------- BusLogic SCSI Host Adapters directly implement SCSI-2 Tagged Queuing, and so support has been included in the driver to utilize tagged queuing with any @@ -150,7 +161,8 @@ o Performance Features queue depth of 1 is selected. Tagged queuing is also disabled for individual target devices if disconnect/reconnect is disabled for that device. -o Robustness Features +Robustness Features +------------------- The driver implements extensive error recovery procedures. When the higher level parts of the SCSI subsystem request that a timed out command be reset, @@ -174,7 +186,8 @@ o Robustness Features lock up or crash, and thereby allowing a clean shutdown and restart after the offending component is removed. -o PCI Configuration Support +PCI Configuration Support +------------------------- On PCI systems running kernels compiled with PCI BIOS support enabled, this driver will interrogate the PCI configuration space and use the I/O port @@ -184,19 +197,22 @@ o PCI Configuration Support used to disable the ISA compatible I/O port entirely as it is not necessary. The ISA compatible I/O port is disabled by default on the BT-948/958/958D. -o /proc File System Support +/proc File System Support +------------------------- Copies of the host adapter configuration information together with updated data transfer and error recovery statistics are available through the /proc/scsi/BusLogic/<N> interface. -o Shared Interrupts Support +Shared Interrupts Support +------------------------- On systems that support shared interrupts, any number of BusLogic Host Adapters may share the same interrupt request channel. - SUPPORTED HOST ADAPTERS +Supported Host Adapters +======================= The following list comprises the supported BusLogic SCSI Host Adapters as of the date of this document. It is recommended that anyone purchasing a BusLogic @@ -205,6 +221,7 @@ that it is or will be supported. FlashPoint Series PCI Host Adapters: +======================= ============================================= FlashPoint LT (BT-930) Ultra SCSI-3 FlashPoint LT (BT-930R) Ultra SCSI-3 with RAIDPlus FlashPoint LT (BT-920) Ultra SCSI-3 (BT-930 without BIOS) @@ -214,15 +231,19 @@ FlashPoint LW (BT-950) Wide Ultra SCSI-3 FlashPoint LW (BT-950R) Wide Ultra SCSI-3 with RAIDPlus FlashPoint DW (BT-952) Dual Channel Wide Ultra SCSI-3 FlashPoint DW (BT-952R) Dual Channel Wide Ultra SCSI-3 with RAIDPlus +======================= ============================================= MultiMaster "W" Series Host Adapters: +======= === ============================== BT-948 PCI Ultra SCSI-3 BT-958 PCI Wide Ultra SCSI-3 BT-958D PCI Wide Differential Ultra SCSI-3 +======= === ============================== MultiMaster "C" Series Host Adapters: +======== ==== ============================== BT-946C PCI Fast SCSI-2 BT-956C PCI Wide Fast SCSI-2 BT-956CD PCI Wide Differential Fast SCSI-2 @@ -232,9 +253,11 @@ BT-757C EISA Wide Fast SCSI-2 BT-757CD EISA Wide Differential Fast SCSI-2 BT-545C ISA Fast SCSI-2 BT-540CF ISA Fast SCSI-2 +======== ==== ============================== MultiMaster "S" Series Host Adapters: +======= ==== ============================== BT-445S VLB Fast SCSI-2 BT-747S EISA Fast SCSI-2 BT-747D EISA Differential Fast SCSI-2 @@ -244,11 +267,14 @@ BT-545S ISA Fast SCSI-2 BT-542D ISA Differential Fast SCSI-2 BT-742A EISA SCSI-2 (742A revision H) BT-542B ISA SCSI-2 (542B revision H) +======= ==== ============================== MultiMaster "A" Series Host Adapters: +======= ==== ============================== BT-742A EISA SCSI-2 (742A revisions A - G) BT-542B ISA SCSI-2 (542B revisions A - G) +======= ==== ============================== AMI FastDisk Host Adapters that are true BusLogic MultiMaster clones are also supported by this driver. @@ -260,9 +286,11 @@ list. The retail kit includes the bare board and manual as well as cabling and driver media and documentation that are not provided with bare boards. - FLASHPOINT INSTALLATION NOTES +FlashPoint Installation Notes +============================= -o RAIDPlus Support +RAIDPlus Support +---------------- FlashPoint Host Adapters now include RAIDPlus, Mylex's bootable software RAID. RAIDPlus is not supported on Linux, and there are no plans to support @@ -273,7 +301,8 @@ o RAIDPlus Support than RAIDPlus, so there is little impetus to include RAIDPlus support in the BusLogic driver. -o Enabling UltraSCSI Transfers +Enabling UltraSCSI Transfers +---------------------------- FlashPoint Host Adapters ship with their configuration set to "Factory Default" settings that are conservative and do not allow for UltraSCSI speed @@ -287,12 +316,14 @@ o Enabling UltraSCSI Transfers the "Optimum Performance" settings are loaded. - BT-948/958/958D INSTALLATION NOTES +BT-948/958/958D Installation Notes +================================== The BT-948/958/958D PCI Ultra SCSI Host Adapters have some features which may require attention in some circumstances when installing Linux. -o PCI I/O Port Assignments +PCI I/O Port Assignments +------------------------ When configured to factory default settings, the BT-948/958/958D will only recognize the PCI I/O port assignments made by the motherboard's PCI BIOS. @@ -312,7 +343,8 @@ o PCI I/O Port Assignments possible future I/O port conflicts. The older BT-946C/956C/956CD also have this configuration option, but the factory default setting is "Primary". -o PCI Slot Scanning Order +PCI Slot Scanning Order +----------------------- In systems with multiple BusLogic PCI Host Adapters, the order in which the PCI slots are scanned may appear reversed with the BT-948/958/958D as @@ -339,7 +371,8 @@ o PCI Slot Scanning Order so as to recognize the host adapters in the same order as they are enumerated by the host adapter's BIOS. -o Enabling UltraSCSI Transfers +Enabling UltraSCSI Transfers +---------------------------- The BT-948/958/958D ship with their configuration set to "Factory Default" settings that are conservative and do not allow for UltraSCSI speed to be @@ -353,7 +386,8 @@ o Enabling UltraSCSI Transfers "Optimum Performance" settings are loaded. - DRIVER OPTIONS +Driver Options +============== BusLogic Driver Options may be specified either via the Linux Kernel Command Line or via the Loadable Kernel Module Installation Facility. Driver Options @@ -520,30 +554,34 @@ The following examples demonstrate setting the Queue Depth for Target Devices Devices on the second host adapter to 31, and the Bus Settle Time on the second host adapter to 30 seconds. -Linux Kernel Command Line: +Linux Kernel Command Line:: linux BusLogic=QueueDepth:[,7,15];QueueDepth:31,BusSettleTime:30 -LILO Linux Boot Loader (in /etc/lilo.conf): +LILO Linux Boot Loader (in /etc/lilo.conf):: append = "BusLogic=QueueDepth:[,7,15];QueueDepth:31,BusSettleTime:30" -INSMOD Loadable Kernel Module Installation Facility: +INSMOD Loadable Kernel Module Installation Facility:: insmod BusLogic.o \ 'BusLogic="QueueDepth:[,7,15];QueueDepth:31,BusSettleTime:30"' -NOTE: Module Utilities 2.1.71 or later is required for correct parsing + +.. Note:: + + Module Utilities 2.1.71 or later is required for correct parsing of driver options containing commas. - DRIVER INSTALLATION +Driver Installation +=================== This distribution was prepared for Linux kernel version 2.0.35, but should be compatible with 2.0.4 or any later 2.0 series kernel. To install the new BusLogic SCSI driver, you may use the following commands, -replacing "/usr/src" with wherever you keep your Linux kernel source tree: +replacing "/usr/src" with wherever you keep your Linux kernel source tree:: cd /usr/src tar -xvzf BusLogic-2.0.15.tar.gz @@ -557,7 +595,8 @@ Then install "arch/x86/boot/zImage" as your standard kernel, run lilo if appropriate, and reboot. - BUSLOGIC ANNOUNCEMENTS MAILING LIST +BusLogic Announcements Mailing List +=================================== The BusLogic Announcements Mailing List provides a forum for informing Linux users of new driver releases and other announcements regarding Linux support diff --git a/Documentation/scsi/FlashPoint.rst b/Documentation/scsi/FlashPoint.rst new file mode 100644 index 000000000000..ef3c07e94ad6 --- /dev/null +++ b/Documentation/scsi/FlashPoint.rst @@ -0,0 +1,176 @@ +.. SPDX-License-Identifier: GPL-2.0 + +=================================== +The BusLogic FlashPoint SCSI Driver +=================================== + +The BusLogic FlashPoint SCSI Host Adapters are now fully supported on Linux. +The upgrade program described below has been officially terminated effective +31 March 1997 since it is no longer needed. + +:: + + MYLEX INTRODUCES LINUX OPERATING SYSTEM SUPPORT FOR ITS + BUSLOGIC FLASHPOINT LINE OF SCSI HOST ADAPTERS + + + FREMONT, CA, -- October 8, 1996 -- Mylex Corporation has expanded Linux + operating system support to its BusLogic brand of FlashPoint Ultra SCSI + host adapters. All of BusLogic's other SCSI host adapters, including the + MultiMaster line, currently support the Linux operating system. Linux + drivers and information will be available on October 15th at + http://sourceforge.net/projects/dandelion/. + + "Mylex is committed to supporting the Linux community," says Peter Shambora, + vice president of marketing for Mylex. "We have supported Linux driver + development and provided technical support for our host adapters for several + years, and are pleased to now make our FlashPoint products available to this + user base." + +The Linux Operating System +========================== + +Linux is a freely-distributed implementation of UNIX for Intel x86, Sun +SPARC, SGI MIPS, Motorola 68k, Digital Alpha AXP and Motorola PowerPC +machines. It supports a wide range of software, including the X Window +System, Emacs, and TCP/IP networking. Further information is available at +http://www.linux.org and http://www.ssc.com/. + +FlashPoint Host Adapters +======================== + +The FlashPoint family of Ultra SCSI host adapters, designed for workstation +and file server environments, are available in narrow, wide, dual channel, +and dual channel wide versions. These adapters feature SeqEngine +automation technology, which minimizes SCSI command overhead and reduces +the number of interrupts generated to the CPU. + +About Mylex +=========== + +Mylex Corporation (NASDAQ/NM SYMBOL: MYLX), founded in 1983, is a leading +producer of RAID technology and network management products. The company +produces high performance disk array (RAID) controllers, and complementary +computer products for network servers, mass storage systems, workstations +and system boards. Through its wide range of RAID controllers and its +BusLogic line of Ultra SCSI host adapter products, Mylex provides enabling +intelligent I/O technologies that increase network management control, +enhance CPU utilization, optimize I/O performance, and ensure data security +and availability. Products are sold globally through a network of OEMs, +major distributors, VARs, and system integrators. Mylex Corporation is +headquartered at 34551 Ardenwood Blvd., Fremont, CA. + +Contact: +======== + +:: + + Peter Shambora + Vice President of Marketing + Mylex Corp. + 510/796-6100 + peters@mylex.com + + +:: + + ANNOUNCEMENT + BusLogic FlashPoint LT/BT-948 Upgrade Program + 1 February 1996 + + ADDITIONAL ANNOUNCEMENT + BusLogic FlashPoint LW/BT-958 Upgrade Program + 14 June 1996 + + Ever since its introduction last October, the BusLogic FlashPoint LT has + been problematic for members of the Linux community, in that no Linux + drivers have been available for this new Ultra SCSI product. Despite its + officially being positioned as a desktop workstation product, and not being + particularly well suited for a high performance multitasking operating + system like Linux, the FlashPoint LT has been touted by computer system + vendors as the latest thing, and has been sold even on many of their high + end systems, to the exclusion of the older MultiMaster products. This has + caused grief for many people who inadvertently purchased a system expecting + that all BusLogic SCSI Host Adapters |
