summaryrefslogtreecommitdiff
path: root/tools/perf
diff options
context:
space:
mode:
authorMark Brown <broonie@kernel.org>2021-06-21 19:28:42 +0100
committerMark Brown <broonie@kernel.org>2021-06-21 19:28:42 +0100
commit9d598cd737d15b5770c5bddf35a512f7ab07b78b (patch)
treed0ec62945d9fb27aa1ac7231247c5c1f42813d12 /tools/perf
parent57c045bc727001c43b6a65adb0418aa7b3e6dbd0 (diff)
parentd55444adedaee5a3024c61637032057fcf38491b (diff)
downloadlinux-9d598cd737d15b5770c5bddf35a512f7ab07b78b.tar.gz
linux-9d598cd737d15b5770c5bddf35a512f7ab07b78b.tar.bz2
linux-9d598cd737d15b5770c5bddf35a512f7ab07b78b.zip
Merge series "Extend regulator notification support" from Matti Vaittinen <matti.vaittinen@fi.rohmeurope.com>:
Extend regulator notification support This series extends the regulator notification and error flag support. Initial discussion on the topic can be found here: https://lore.kernel.org/lkml/6046836e22b8252983f08d5621c35ececb97820d.camel@fi.rohmeurope.com/ In a nutshell - the series adds: 1. WARNING level events/error flags. (Patch 3) Current regulator 'ERROR' event notifications for over/under voltage, over current and over temperature are used to indicate condition where monitored entity is so badly "off" that it actually indicates a hardware error which can not be recovered. The most typical hanling for that is believed to be a (graceful) system-shutdown. Here we add set of 'WARNING' level flags to allow sending notifications to consumers before things are 'that badly off' so that consumer drivers can implement recovery-actions. 2. Device-tree properties for specifying limit values. (Patches 1, 5) Add limits for above mentioned 'ERROR' and 'WARNING' levels (which send notifications to consumers) and also for a 'PROTECTION' level (which will be used to immediately shut-down the regulator(s) W/O informing consumer drivers. Typically implemented by hardware). Property parsing is implemented in regulator core which then calls callback operations for limit setting from the IC drivers. A warning is emitted if protection is requested by device tree but the underlying IC does not support configuring requested protection. 3. Helpers which can be registered by IC. (Patch 4) Target is to avoid implementing IRQ handling and IRQ storm protection in each IC driver. (Many of the ICs implementin these IRQs do not allow masking or acking the IRQ but keep the IRQ asserted for the whole duration of problem keeping the processor in IRQ handling loop). 4. Emergency poweroff function (refactored out of the thermal_core to kernel/reboot.c) which is called if IC fires error IRQs but IC reading fails and given retry-count is exceeded. (Patches 2, 4) Please note that the mutex in the emergency shutdown was replaced by a simple atomic in order to allow call from any context. The helper was attempted to be done so it could be used to implement roughly same logic as is used in qcom-labibb regulator. This means amongst other things a safety shut-down if IC registers are not readable. Using these shut-down retry counters are optional. The idea is that the helper could be also used by simpler ICs which do not provide status register(s) which can be used to check if error is still active. ICs which do not have such status register can simply omit the 'renable' callback (and retry-counts etc) - and helper assumes the situation is Ok and re-enables IRQ after given time period. If problem persists the handler is ran again and another notification is sent - but at least the delay allows processor to avoid IRQ loop. Patch 7 takes this notification support in use at BD9576MUF. Patch 8 is related to MFD change which is not really related to the RFC here. It was added to this series in order to avoid potential conflicts. Patch 9 adds a maintainers entry. Changelog v10-RESEND: - rebased on v5.13-rc4 Changelog v10: - rebased on v5.13-rc2 - Move rdev_*() print macros to the internal.h and use rdev_dbg() from irq_helpers.c - Export rdev_get_name() and move it from coupler.h to driver.h for others to use. (It was already in coupler.h but not exported - usage was limited and coupler.h does not sound like optimal place as rdev_name is not only used by coupled regulators) - Send all regulator notifications from irq_helpers.c at one OR'd event for the sake of simplicity. For BD9576 this does not matter as it has own IRQ for each event case. Header defining events says they may be OR'd. - Change WARN() at protection shutdown to pr_emerg as suggested by Petr. Changelog v9: - rebases on v5.13-rc1 - Update thermal documentation - Fix regulator notification event number Changelog v8: - split shutdown API adding and thermal core taking it in use to own patches. - replace the spinlock with atomic when ensuring the emergency shutdown is only called once. Changelog v7: general: - rebased on v5.12-rc7 - new patch for refactoring the hw-failure reboot logic out of thermal_core.c for others to use. notification helpers: - fix regulator error_flags query - grammar/typos - do not BUG() but attempt to shut-down the system - use BITS_PER_TYPE() Changelog v6: Add MAINTAINERS entry Changes to IRQ notifiers - move devm functions to drivers/regulator/devres.c - drop irq validity check - use devm_add_action_or_reset() - fix styling issues - fix kerneldocs Changelog v5: - Fix the badly formatted pr_emerg() call. Changelog v4: - rebased on v5.12-rc6 - dropped RFC - fix external FET DT-binding. - improve prints for cases when expecting HW failure. - styling and typos Changelog v3: Regulator core: - Fix dangling pointer access at regulator_irq_helper() stpmic1_regulator: - fix function prototype (compile error) bd9576-regulator: - Update over current limits to what was given in new data-sheet (REV00K) - Allow over-current monitoring without external FET. Set limits to values given in data-sheet (REV00K). Changelog v2: Generic: - rebase on v5.12-rc2 + BD9576 series - Split devm variant of delayed wq to own series Regulator framework: - Provide non devm variant of IRQ notification helpers - shorten dt-property names as suggested by Rob - unconditionally call map_event in IRQ handling and require it to be populated BD9576 regulators: - change the FET resistance property to micro-ohms - fix voltage computation in OC limit setting
Diffstat (limited to 'tools/perf')
-rw-r--r--tools/perf/Documentation/perf-intel-pt.txt6
-rw-r--r--tools/perf/Documentation/perf-script.txt7
-rw-r--r--tools/perf/Makefile.config1
-rw-r--r--tools/perf/arch/arm64/util/kvm-stat.c2
-rw-r--r--tools/perf/arch/mips/entry/syscalls/syscall_n64.tbl5
-rw-r--r--tools/perf/arch/powerpc/entry/syscalls/syscall.tbl4
-rw-r--r--tools/perf/arch/s390/entry/syscalls/syscall.tbl4
-rw-r--r--tools/perf/arch/x86/entry/syscalls/syscall_64.tbl4
-rw-r--r--tools/perf/builtin-buildid-list.c3
-rw-r--r--tools/perf/builtin-stat.c13
-rw-r--r--tools/perf/perf.c4
-rw-r--r--tools/perf/pmu-events/arch/powerpc/power10/cache.json30
-rw-r--r--tools/perf/pmu-events/arch/powerpc/power10/floating_point.json2
-rw-r--r--tools/perf/pmu-events/arch/powerpc/power10/frontend.json124
-rw-r--r--tools/perf/pmu-events/arch/powerpc/power10/locks.json4
-rw-r--r--tools/perf/pmu-events/arch/powerpc/power10/marked.json61
-rw-r--r--tools/perf/pmu-events/arch/powerpc/power10/memory.json79
-rw-r--r--tools/perf/pmu-events/arch/powerpc/power10/others.json133
-rw-r--r--tools/perf/pmu-events/arch/powerpc/power10/pipeline.json135
-rw-r--r--tools/perf/pmu-events/arch/powerpc/power10/pmc.json8
-rw-r--r--tools/perf/pmu-events/arch/powerpc/power10/translation.json22
-rw-r--r--tools/perf/pmu-events/jevents.c8
-rwxr-xr-xtools/perf/scripts/python/exported-sql-viewer.py12
-rw-r--r--tools/perf/tests/attr/base-record2
-rw-r--r--tools/perf/tests/attr/base-stat2
-rw-r--r--tools/perf/tests/attr/system-wide-dummy2
-rw-r--r--tools/perf/tests/pfm.c4
-rw-r--r--tools/perf/util/Build7
-rw-r--r--tools/perf/util/bpf_counter.c4
-rw-r--r--tools/perf/util/event.h2
-rw-r--r--tools/perf/util/evlist.c3
-rw-r--r--tools/perf/util/intel-pt-decoder/intel-pt-decoder.c6
-rw-r--r--tools/perf/util/intel-pt.c6
-rw-r--r--tools/perf/util/parse-events.c13
-rw-r--r--tools/perf/util/parse-events.l1
-rw-r--r--tools/perf/util/pfm.c11
-rw-r--r--tools/perf/util/record.c8
-rw-r--r--tools/perf/util/session.c4
38 files changed, 409 insertions, 337 deletions
diff --git a/tools/perf/Documentation/perf-intel-pt.txt b/tools/perf/Documentation/perf-intel-pt.txt
index 1dcec73c910c..bcf3eca5afbe 100644
--- a/tools/perf/Documentation/perf-intel-pt.txt
+++ b/tools/perf/Documentation/perf-intel-pt.txt
@@ -108,9 +108,9 @@ displayed as follows:
perf script --itrace=ibxwpe -F+flags
-The flags are "bcrosyiABEx" which stand for branch, call, return, conditional,
-system, asynchronous, interrupt, transaction abort, trace begin, trace end, and
-in transaction, respectively.
+The flags are "bcrosyiABExgh" which stand for branch, call, return, conditional,
+system, asynchronous, interrupt, transaction abort, trace begin, trace end,
+in transaction, VM-entry, and VM-exit respectively.
perf script also supports higher level ways to dump instruction traces:
diff --git a/tools/perf/Documentation/perf-script.txt b/tools/perf/Documentation/perf-script.txt
index 5b8b61075039..48a5f5b26dd4 100644
--- a/tools/perf/Documentation/perf-script.txt
+++ b/tools/perf/Documentation/perf-script.txt
@@ -183,14 +183,15 @@ OPTIONS
At this point usage is displayed, and perf-script exits.
The flags field is synthesized and may have a value when Instruction
- Trace decoding. The flags are "bcrosyiABEx" which stand for branch,
+ Trace decoding. The flags are "bcrosyiABExgh" which stand for branch,
call, return, conditional, system, asynchronous, interrupt,
- transaction abort, trace begin, trace end, and in transaction,
+ transaction abort, trace begin, trace end, in transaction, VM-Entry, and VM-Exit
respectively. Known combinations of flags are printed more nicely e.g.
"call" for "bc", "return" for "br", "jcc" for "bo", "jmp" for "b",
"int" for "bci", "iret" for "bri", "syscall" for "bcs", "sysret" for "brs",
"async" for "by", "hw int" for "bcyi", "tx abrt" for "bA", "tr strt" for "bB",
- "tr end" for "bE". However the "x" flag will be display separately in those
+ "tr end" for "bE", "vmentry" for "bcg", "vmexit" for "bch".
+ However the "x" flag will be displayed separately in those
cases e.g. "jcc (x)" for a condition branch within a transaction.
The callindent field is synthesized and may have a value when
diff --git a/tools/perf/Makefile.config b/tools/perf/Makefile.config
index 0d6619064a83..406a9519145e 100644
--- a/tools/perf/Makefile.config
+++ b/tools/perf/Makefile.config
@@ -540,6 +540,7 @@ ifndef NO_LIBELF
ifdef LIBBPF_DYNAMIC
ifeq ($(feature-libbpf), 1)
EXTLIBS += -lbpf
+ $(call detected,CONFIG_LIBBPF_DYNAMIC)
else
dummy := $(error Error: No libbpf devel library found, please install libbpf-devel);
endif
diff --git a/tools/perf/arch/arm64/util/kvm-stat.c b/tools/perf/arch/arm64/util/kvm-stat.c
index 2303256b7d05..73d18e0ed6f6 100644
--- a/tools/perf/arch/arm64/util/kvm-stat.c
+++ b/tools/perf/arch/arm64/util/kvm-stat.c
@@ -71,7 +71,7 @@ struct kvm_reg_events_ops kvm_reg_events_ops[] = {
.name = "vmexit",
.ops = &exit_events,
},
- { NULL },
+ { NULL, NULL },
};
const char * const kvm_skip_events[] = {
diff --git a/tools/perf/arch/mips/entry/syscalls/syscall_n64.tbl b/tools/perf/arch/mips/entry/syscalls/syscall_n64.tbl
index 91649690b52f..9cd1c34f31b5 100644
--- a/tools/perf/arch/mips/entry/syscalls/syscall_n64.tbl
+++ b/tools/perf/arch/mips/entry/syscalls/syscall_n64.tbl
@@ -356,3 +356,8 @@
439 n64 faccessat2 sys_faccessat2
440 n64 process_madvise sys_process_madvise
441 n64 epoll_pwait2 sys_epoll_pwait2
+442 n64 mount_setattr sys_mount_setattr
+# 443 reserved for quotactl_path
+444 n64 landlock_create_ruleset sys_landlock_create_ruleset
+445 n64 landlock_add_rule sys_landlock_add_rule
+446 n64 landlock_restrict_self sys_landlock_restrict_self
diff --git a/tools/perf/arch/powerpc/entry/syscalls/syscall.tbl b/tools/perf/arch/powerpc/entry/syscalls/syscall.tbl
index 0b2480cf3e47..8f052ff4058c 100644
--- a/tools/perf/arch/powerpc/entry/syscalls/syscall.tbl
+++ b/tools/perf/arch/powerpc/entry/syscalls/syscall.tbl
@@ -522,3 +522,7 @@
440 common process_madvise sys_process_madvise
441 common epoll_pwait2 sys_epoll_pwait2 compat_sys_epoll_pwait2
442 common mount_setattr sys_mount_setattr
+# 443 reserved for quotactl_path
+444 common landlock_create_ruleset sys_landlock_create_ruleset
+445 common landlock_add_rule sys_landlock_add_rule
+446 common landlock_restrict_self sys_landlock_restrict_self
diff --git a/tools/perf/arch/s390/entry/syscalls/syscall.tbl b/tools/perf/arch/s390/entry/syscalls/syscall.tbl
index 3abef2144dac..0690263df1dd 100644
--- a/tools/perf/arch/s390/entry/syscalls/syscall.tbl
+++ b/tools/perf/arch/s390/entry/syscalls/syscall.tbl
@@ -445,3 +445,7 @@
440 common process_madvise sys_process_madvise sys_process_madvise
441 common epoll_pwait2 sys_epoll_pwait2 compat_sys_epoll_pwait2
442 common mount_setattr sys_mount_setattr sys_mount_setattr
+# 443 reserved for quotactl_path
+444 common landlock_create_ruleset sys_landlock_create_ruleset sys_landlock_create_ruleset
+445 common landlock_add_rule sys_landlock_add_rule sys_landlock_add_rule
+446 common landlock_restrict_self sys_landlock_restrict_self sys_landlock_restrict_self
diff --git a/tools/perf/arch/x86/entry/syscalls/syscall_64.tbl b/tools/perf/arch/x86/entry/syscalls/syscall_64.tbl
index 7bf01cbe582f..ce18119ea0d0 100644
--- a/tools/perf/arch/x86/entry/syscalls/syscall_64.tbl
+++ b/tools/perf/arch/x86/entry/syscalls/syscall_64.tbl
@@ -364,6 +364,10 @@
440 common process_madvise sys_process_madvise
441 common epoll_pwait2 sys_epoll_pwait2
442 common mount_setattr sys_mount_setattr
+# 443 reserved for quotactl_path
+444 common landlock_create_ruleset sys_landlock_create_ruleset
+445 common landlock_add_rule sys_landlock_add_rule
+446 common landlock_restrict_self sys_landlock_restrict_self
#
# Due to a historical design error, certain syscalls are numbered differently
diff --git a/tools/perf/builtin-buildid-list.c b/tools/perf/builtin-buildid-list.c
index 87f5b1a4a7fa..833405c27dae 100644
--- a/tools/perf/builtin-buildid-list.c
+++ b/tools/perf/builtin-buildid-list.c
@@ -80,6 +80,9 @@ static int perf_session__list_build_ids(bool force, bool with_hits)
if (!perf_header__has_feat(&session->header, HEADER_BUILD_ID))
with_hits = true;
+ if (zstd_init(&(session->zstd_data), 0) < 0)
+ pr_warning("Decompression initialization failed. Reported data may be incomplete.\n");
+
/*
* in pipe-mode, the only way to get the buildids is to parse
* the record stream. Buildids are stored as RECORD_HEADER_BUILD_ID
diff --git a/tools/perf/builtin-stat.c b/tools/perf/builtin-stat.c
index 5a830ae09418..f9f74a514315 100644
--- a/tools/perf/builtin-stat.c
+++ b/tools/perf/builtin-stat.c
@@ -572,7 +572,8 @@ static int enable_counters(void)
* - we have initial delay configured
*/
if (!target__none(&target) || stat_config.initial_delay) {
- evlist__enable(evsel_list);
+ if (!all_counters_use_bpf)
+ evlist__enable(evsel_list);
if (stat_config.initial_delay > 0)
pr_info(EVLIST_ENABLED_MSG);
}
@@ -581,13 +582,19 @@ static int enable_counters(void)
static void disable_counters(void)
{
+ struct evsel *counter;
+
/*
* If we don't have tracee (attaching to task or cpu), counters may
* still be running. To get accurate group ratios, we must stop groups
* from counting before reading their constituent counters.
*/
- if (!target__none(&target))
- evlist__disable(evsel_list);
+ if (!target__none(&target)) {
+ evlist__for_each_entry(evsel_list, counter)
+ bpf_counter__disable(counter);
+ if (!all_counters_use_bpf)
+ evlist__disable(evsel_list);
+ }
}
static volatile int workload_exec_errno;
diff --git a/tools/perf/perf.c b/tools/perf/perf.c
index 20cb91ef06ff..2f6b67189b42 100644
--- a/tools/perf/perf.c
+++ b/tools/perf/perf.c
@@ -443,6 +443,8 @@ int main(int argc, const char **argv)
const char *cmd;
char sbuf[STRERR_BUFSIZE];
+ perf_debug_setup();
+
/* libsubcmd init */
exec_cmd_init("perf", PREFIX, PERF_EXEC_PATH, EXEC_PATH_ENVIRONMENT);
pager_init(PERF_PAGER_ENVIRONMENT);
@@ -531,8 +533,6 @@ int main(int argc, const char **argv)
*/
pthread__block_sigwinch();
- perf_debug_setup();
-
while (1) {
static int done_help;
diff --git a/tools/perf/pmu-events/arch/powerpc/power10/cache.json b/tools/perf/pmu-events/arch/powerpc/power10/cache.json
index 616f29098c71..605be14f441c 100644
--- a/tools/perf/pmu-events/arch/powerpc/power10/cache.json
+++ b/tools/perf/pmu-events/arch/powerpc/power10/cache.json
@@ -1,46 +1,56 @@
[
{
- "EventCode": "1003C",
+ "EventCode": "0x1003C",
"EventName": "PM_EXEC_STALL_DMISS_L2L3",
"BriefDescription": "Cycles in which the oldest instruction in the pipeline was waiting for a load miss to resolve from either the local L2 or local L3."
},
{
- "EventCode": "34056",
+ "EventCode": "0x1E054",
+ "EventName": "PM_EXEC_STALL_DMISS_L21_L31",
+ "BriefDescription": "Cycles in which the oldest instruction in the pipeline was waiting for a load miss to resolve from another core's L2 or L3 on the same chip."
+ },
+ {
+ "EventCode": "0x34054",
+ "EventName": "PM_EXEC_STALL_DMISS_L2L3_NOCONFLICT",
+ "BriefDescription": "Cycles in which the oldest instruction in the pipeline was waiting for a load miss to resolve from the local L2 or local L3, without a dispatch conflict."
+ },
+ {
+ "EventCode": "0x34056",
"EventName": "PM_EXEC_STALL_LOAD_FINISH",
- "BriefDescription": "Cycles in which the oldest instruction in the pipeline was finishing a load after its data was reloaded from a data source beyond the local L1; cycles in which the LSU was processing an L1-hit; cycles in which the NTF instruction merged with another load in the LMQ."
+ "BriefDescription": "Cycles in which the oldest instruction in the pipeline was finishing a load after its data was reloaded from a data source beyond the local L1; cycles in which the LSU was processing an L1-hit; cycles in which the NTF instruction merged with another load in the LMQ; cycles in which the NTF instruction is waiting for a data reload for a load miss, but the data comes back with a non-NTF instruction."
},
{
- "EventCode": "3006C",
+ "EventCode": "0x3006C",
"EventName": "PM_RUN_CYC_SMT2_MODE",
"BriefDescription": "Cycles when this thread's run latch is set and the core is in SMT2 mode."
},
{
- "EventCode": "300F4",
+ "EventCode": "0x300F4",
"EventName": "PM_RUN_INST_CMPL_CONC",
"BriefDescription": "PowerPC instructions completed by this thread when all threads in the core had the run-latch set."
},
{
- "EventCode": "4C016",
+ "EventCode": "0x4C016",
"EventName": "PM_EXEC_STALL_DMISS_L2L3_CONFLICT",
"BriefDescription": "Cycles in which the oldest instruction in the pipeline was waiting for a load miss to resolve from the local L2 or local L3, with a dispatch conflict."
},
{
- "EventCode": "4D014",
+ "EventCode": "0x4D014",
"EventName": "PM_EXEC_STALL_LOAD",
"BriefDescription": "Cycles in which the oldest instruction in the pipeline was a load instruction executing in the Load Store Unit."
},
{
- "EventCode": "4D016",
+ "EventCode": "0x4D016",
"EventName": "PM_EXEC_STALL_PTESYNC",
"BriefDescription": "Cycles in which the oldest instruction in the pipeline was a PTESYNC instruction executing in the Load Store Unit."
},
{
- "EventCode": "401EA",
+ "EventCode": "0x401EA",
"EventName": "PM_THRESH_EXC_128",
"BriefDescription": "Threshold counter exceeded a value of 128."
},
{
- "EventCode": "400F6",
+ "EventCode": "0x400F6",
"EventName": "PM_BR_MPRED_CMPL",
"BriefDescription": "A mispredicted branch completed. Includes direction and target."
}
diff --git a/tools/perf/pmu-events/arch/powerpc/power10/floating_point.json b/tools/perf/pmu-events/arch/powerpc/power10/floating_point.json
index 703cd431ae5b..54acb55e2c8c 100644
--- a/tools/perf/pmu-events/arch/powerpc/power10/floating_point.json
+++ b/tools/perf/pmu-events/arch/powerpc/power10/floating_point.json
@@ -1,6 +1,6 @@
[
{
- "EventCode": "4016E",
+ "EventCode": "0x4016E",
"EventName": "PM_THRESH_NOT_MET",
"BriefDescription": "Threshold counter did not meet threshold."
}
diff --git a/tools/perf/pmu-events/arch/powerpc/power10/frontend.json b/tools/perf/pmu-events/arch/powerpc/power10/frontend.json
index eac8609dcc90..558f9530f54e 100644
--- a/tools/perf/pmu-events/arch/powerpc/power10/frontend.json
+++ b/tools/perf/pmu-events/arch/powerpc/power10/frontend.json
@@ -1,216 +1,246 @@
[
{
- "EventCode": "10004",
+ "EventCode": "0x10004",
"EventName": "PM_EXEC_STALL_TRANSLATION",
"BriefDescription": "Cycles in which the oldest instruction in the pipeline suffered a TLB miss or ERAT miss and waited for it to resolve."
},
{
- "EventCode": "10010",
+ "EventCode": "0x10006",
+ "EventName": "PM_DISP_STALL_HELD_OTHER_CYC",
+ "BriefDescription": "Cycles in which the NTC instruction is held at dispatch for any other reason."
+ },
+ {
+ "EventCode": "0x10010",
"EventName": "PM_PMC4_OVERFLOW",
"BriefDescription": "The event selected for PMC4 caused the event counter to overflow."
},
{
- "EventCode": "10020",
+ "EventCode": "0x10020",
"EventName": "PM_PMC4_REWIND",
"BriefDescription": "The speculative event selected for PMC4 rewinds and the counter for PMC4 is not charged."
},
{
- "EventCode": "10038",
+ "EventCode": "0x10038",
"EventName": "PM_DISP_STALL_TRANSLATION",
"BriefDescription": "Cycles when dispatch was stalled for this thread because the MMU was handling a translation miss."
},
{
- "EventCode": "1003A",
+ "EventCode": "0x1003A",
"EventName": "PM_DISP_STALL_BR_MPRED_IC_L2",
"BriefDescription": "Cycles when dispatch was stalled while the instruction was fetched from the local L2 after suffering a branch mispredict."
},
{
- "EventCode": "1E050",
+ "EventCode": "0x1D05E",
+ "EventName": "PM_DISP_STALL_HELD_HALT_CYC",
+ "BriefDescription": "Cycles in which the NTC instruction is held at dispatch because of power management."
+ },
+ {
+ "EventCode": "0x1E050",
"EventName": "PM_DISP_STALL_HELD_STF_MAPPER_CYC",
"BriefDescription": "Cycles in which the NTC instruction is held at dispatch because the STF mapper/SRB was full. Includes GPR (count, link, tar), VSR, VMR, FPR."
},
{
- "EventCode": "1F054",
+ "EventCode": "0x1F054",
"EventName": "PM_DTLB_HIT",
"BriefDescription": "The PTE required by the instruction was resident in the TLB (data TLB access). When MMCR1[16]=0 this event counts only demand hits. When MMCR1[16]=1 this event includes demand and prefetch. Applies to both HPT and RPT."
},
{
- "EventCode": "101E8",
+ "EventCode": "0x10064",
+ "EventName": "PM_DISP_STALL_IC_L2",
+ "BriefDescription": "Cycles when dispatch was stalled while the instruction was fetched from the local L2."
+ },
+ {
+ "EventCode": "0x101E8",
"EventName": "PM_THRESH_EXC_256",
"BriefDescription": "Threshold counter exceeded a count of 256."
},
{
- "EventCode": "101EC",
+ "EventCode": "0x101EC",
"EventName": "PM_THRESH_MET",
"BriefDescription": "Threshold exceeded."
},
{
- "EventCode": "100F2",
+ "EventCode": "0x100F2",
"EventName": "PM_1PLUS_PPC_CMPL",
"BriefDescription": "Cycles in which at least one instruction is completed by this thread."
},
{
- "EventCode": "100F6",
+ "EventCode": "0x100F6",
"EventName": "PM_IERAT_MISS",
"BriefDescription": "IERAT Reloaded to satisfy an IERAT miss. All page sizes are counted by this event."
},
{
- "EventCode": "100F8",
+ "EventCode": "0x100F8",
"EventName": "PM_DISP_STALL_CYC",
"BriefDescription": "Cycles the ICT has no itags assigned to this thread (no instructions were dispatched during these cycles)."
},
{
- "EventCode": "20114",
+ "EventCode": "0x20006",
+ "EventName": "PM_DISP_STALL_HELD_ISSQ_FULL_CYC",
+ "BriefDescription": "Cycles in which the NTC instruction is held at dispatch due to Issue queue full. Includes issue queue and branch queue."
+ },
+ {
+ "EventCode": "0x20114",
"EventName": "PM_MRK_L2_RC_DISP",
"BriefDescription": "Marked instruction RC dispatched in L2."
},
{
- "EventCode": "2C010",
+ "EventCode": "0x2C010",
"EventName": "PM_EXEC_STALL_LSU",
"BriefDescription": "Cycles in which the oldest instruction in the pipeline was executing in the Load Store Unit. This does not include simple fixed point instructions."
},
{
- "EventCode": "2C016",
+ "EventCode": "0x2C016",
"EventName": "PM_DISP_STALL_IERAT_ONLY_MISS",
"BriefDescription": "Cycles when dispatch was stalled while waiting to resolve an instruction ERAT miss."
},
{
- "EventCode": "2C01E",
+ "EventCode": "0x2C01E",
"EventName": "PM_DISP_STALL_BR_MPRED_IC_L3",
"BriefDescription": "Cycles when dispatch was stalled while the instruction was fetched from the local L3 after suffering a branch mispredict."
},
{
- "EventCode": "2D01A",
+ "EventCode": "0x2D01A",
"EventName": "PM_DISP_STALL_IC_MISS",
"BriefDescription": "Cycles when dispatch was stalled for this thread due to an Icache Miss."
},
{
- "EventCode": "2D01C",
- "EventName": "PM_CMPL_STALL_STCX",
- "BriefDescription": "Cycles in which the oldest instruction in the pipeline was a stcx waiting for resolution from the nest before completing."
- },
- {
- "EventCode": "2E018",
+ "EventCode": "0x2E018",
"EventName": "PM_DISP_STALL_FETCH",
"BriefDescription": "Cycles when dispatch was stalled for this thread because Fetch was being held."
},
{
- "EventCode": "2E01A",
+ "EventCode": "0x2E01A",
"EventName": "PM_DISP_STALL_HELD_XVFC_MAPPER_CYC",
"BriefDescription": "Cycles in which the NTC instruction is held at dispatch because the XVFC mapper/SRB was full."
},
{
- "EventCode": "2C142",
+ "EventCode": "0x2C142",
"EventName": "PM_MRK_XFER_FROM_SRC_PMC2",
"BriefDescription": "For a marked data transfer instruction, the processor's L1 data cache was reloaded from the source specified in MMCR3[15:27]. If MMCR1[16|17] is 0 (default), this count includes only lines that were reloaded to satisfy a demand miss. If MMCR1[16|17] is 1, this count includes both demand misses and prefetch reloads."
},
{
- "EventCode": "24050",
+ "EventCode": "0x24050",
"EventName": "PM_IOPS_DISP",
"BriefDescription": "Internal Operations dispatched. PM_IOPS_DISP / PM_INST_DISP will show the average number of internal operations per PowerPC instruction."
},
{
- "EventCode": "2405E",
+ "EventCode": "0x2405E",
"EventName": "PM_ISSUE_CANCEL",
"BriefDescription": "An instruction issued and the issue was later cancelled. Only one cancel per PowerPC instruction."
},
{
- "EventCode": "200FA",
+ "EventCode": "0x200FA",
"EventName": "PM_BR_TAKEN_CMPL",
"BriefDescription": "Branch Taken instruction completed."
},
{
- "EventCode": "30012",
+ "EventCode": "0x30004",
+ "EventName": "PM_DISP_STALL_FLUSH",
+ "BriefDescription": "Cycles when dispatch was stalled because of a flush that happened to an instruction(s) that was not yet NTC. PM_EXEC_STALL_NTC_FLUSH only includes instructions that were flushed after becoming NTC."
+ },
+ {
+ "EventCode": "0x3000A",
+ "EventName": "PM_DISP_STALL_ITLB_MISS",
+ "BriefDescription": "Cycles when dispatch was stalled while waiting to resolve an instruction TLB miss."
+ },
+ {
+ "EventCode": "0x30012",
"EventName": "PM_FLUSH_COMPLETION",
"BriefDescription": "The instruction that was next to complete (oldest in the pipeline) did not complete because it suffered a flush."
},
{
- "EventCode": "30014",
+ "EventCode": "0x30014",
"EventName": "PM_EXEC_STALL_STORE",
"BriefDescription": "Cycles in which the oldest instruction in the pipeline was a store instruction executing in the Load Store Unit."
},
{
- "EventCode": "30018",
+ "EventCode": "0x30018",
"EventName": "PM_DISP_STALL_HELD_SCOREBOARD_CYC",
"BriefDescription": "Cycles in which the NTC instruction is held at dispatch while waiting on the Scoreboard. This event combines VSCR and FPSCR together."
},
{
- "EventCode": "30026",
+ "EventCode": "0x30026",
"EventName": "PM_EXEC_STALL_STORE_MISS",
"BriefDescription": "Cycles in which the oldest instruction in the pipeline was a store whose cache line was not resident in the L1 and was waiting for allocation of the missing line into the L1."
},
{
- "EventCode": "3012A",
+ "EventCode": "0x3012A",
"EventName": "PM_MRK_L2_RC_DONE",
"BriefDescription": "L2 RC machine completed the transaction for the marked instruction."
},
{
- "EventCode": "3F046",
+ "EventCode": "0x3F046",
"EventName": "PM_ITLB_HIT_1G",
"BriefDescription": "Instruction TLB hit (IERAT reload) page size 1G, which implies Radix Page Table translation is in use. When MMCR1[17]=0 this event counts only for demand misses. When MMCR1[17]=1 this event includes demand misses and prefetches."