summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
-rw-r--r--Documentation/devicetree/bindings/arm/arm,scmi.txt2
-rw-r--r--Documentation/devicetree/bindings/arm/arm,scpi.txt2
-rw-r--r--Documentation/devicetree/bindings/arm/freescale/fsl,scu.txt2
-rw-r--r--Documentation/devicetree/bindings/arm/marvell/ap80x-system-controller.txt2
-rw-r--r--Documentation/devicetree/bindings/arm/marvell/cp110-system-controller.txt2
-rw-r--r--Documentation/devicetree/bindings/cpufreq/cpufreq-dt.txt3
-rw-r--r--Documentation/devicetree/bindings/cpufreq/cpufreq-mediatek.txt4
-rw-r--r--Documentation/devicetree/bindings/cpufreq/nvidia,tegra20-cpufreq.txt2
-rw-r--r--Documentation/devicetree/bindings/hwmon/gpio-fan.txt3
-rw-r--r--Documentation/devicetree/bindings/hwmon/lm90.txt4
-rw-r--r--Documentation/devicetree/bindings/thermal/allwinner,sun8i-a83t-ths.yaml2
-rw-r--r--Documentation/devicetree/bindings/thermal/amazon,al-thermal.txt2
-rw-r--r--Documentation/devicetree/bindings/thermal/brcm,avs-ro-thermal.yaml2
-rw-r--r--Documentation/devicetree/bindings/thermal/brcm,bcm2835-thermal.txt2
-rw-r--r--Documentation/devicetree/bindings/thermal/hisilicon-thermal.txt2
-rw-r--r--Documentation/devicetree/bindings/thermal/max77620_thermal.txt6
-rw-r--r--Documentation/devicetree/bindings/thermal/mediatek-thermal.txt2
-rw-r--r--Documentation/devicetree/bindings/thermal/nvidia,tegra124-soctherm.txt10
-rw-r--r--Documentation/devicetree/bindings/thermal/nvidia,tegra186-bpmp-thermal.txt2
-rw-r--r--Documentation/devicetree/bindings/thermal/qcom-spmi-temp-alarm.txt2
-rw-r--r--Documentation/devicetree/bindings/thermal/qcom-tsens.yaml1
-rw-r--r--Documentation/devicetree/bindings/thermal/rockchip-thermal.txt2
-rw-r--r--Documentation/devicetree/bindings/thermal/tango-thermal.txt2
-rw-r--r--Documentation/devicetree/bindings/thermal/thermal-generic-adc.txt2
-rw-r--r--Documentation/devicetree/bindings/thermal/thermal.txt586
-rw-r--r--MAINTAINERS8
-rw-r--r--drivers/acpi/thermal.c76
-rw-r--r--drivers/net/ethernet/chelsio/cxgb4/cxgb4_thermal.c8
-rw-r--r--drivers/net/ethernet/mellanox/mlxsw/core_thermal.c91
-rw-r--r--drivers/net/wireless/intel/iwlwifi/mvm/tt.c9
-rw-r--r--drivers/platform/x86/acerhdf.c33
-rw-r--r--drivers/platform/x86/intel_mid_thermal.c6
-rw-r--r--drivers/power/supply/power_supply_core.c9
-rw-r--r--drivers/thermal/Kconfig20
-rw-r--r--drivers/thermal/Makefile6
-rw-r--r--drivers/thermal/armada_thermal.c6
-rw-r--r--drivers/thermal/clock_cooling.c445
-rw-r--r--drivers/thermal/da9062-thermal.c16
-rw-r--r--drivers/thermal/devfreq_cooling.c10
-rw-r--r--drivers/thermal/dove_thermal.c6
-rw-r--r--drivers/thermal/gov_power_allocator.c9
-rw-r--r--drivers/thermal/hisi_thermal.c6
-rw-r--r--drivers/thermal/imx8mm_thermal.c1
-rw-r--r--drivers/thermal/imx_thermal.c60
-rw-r--r--drivers/thermal/intel/int340x_thermal/int3400_thermal.c38
-rw-r--r--drivers/thermal/intel/int340x_thermal/int340x_thermal_zone.c5
-rw-r--r--drivers/thermal/intel/int340x_thermal/processor_thermal_device.c2
-rw-r--r--drivers/thermal/intel/intel_pch_thermal.c8
-rw-r--r--drivers/thermal/intel/intel_quark_dts_thermal.c34
-rw-r--r--drivers/thermal/intel/intel_soc_dts_iosf.c3
-rw-r--r--drivers/thermal/intel/x86_pkg_temp_thermal.c6
-rw-r--r--drivers/thermal/kirkwood_thermal.c7
-rw-r--r--drivers/thermal/mtk_thermal.c234
-rw-r--r--drivers/thermal/qcom/tsens-v0_1.c144
-rw-r--r--drivers/thermal/qcom/tsens.c3
-rw-r--r--drivers/thermal/qcom/tsens.h2
-rw-r--r--drivers/thermal/rcar_gen3_thermal.c10
-rw-r--r--drivers/thermal/rcar_thermal.c9
-rw-r--r--drivers/thermal/rockchip_thermal.c6
-rw-r--r--drivers/thermal/spear_thermal.c7
-rw-r--r--drivers/thermal/sprd_thermal.c6
-rw-r--r--drivers/thermal/st/st_thermal.c5
-rw-r--r--drivers/thermal/thermal_core.c174
-rw-r--r--drivers/thermal/thermal_core.h15
-rw-r--r--drivers/thermal/thermal_helpers.c13
-rw-r--r--drivers/thermal/thermal_netlink.c647
-rw-r--r--drivers/thermal/thermal_netlink.h104
-rw-r--r--drivers/thermal/thermal_of.c41
-rw-r--r--drivers/thermal/thermal_sysfs.c52
-rw-r--r--drivers/thermal/ti-soc-thermal/ti-thermal-common.c2
-rw-r--r--include/linux/clock_cooling.h57
-rw-r--r--include/linux/devfreq_cooling.h9
-rw-r--r--include/linux/thermal.h31
-rw-r--r--include/uapi/linux/thermal.h89
-rw-r--r--net/netlink/genetlink.c2
75 files changed, 1632 insertions, 1609 deletions
diff --git a/Documentation/devicetree/bindings/arm/arm,scmi.txt b/Documentation/devicetree/bindings/arm/arm,scmi.txt
index 1f293ea24cd8..55deb68230eb 100644
--- a/Documentation/devicetree/bindings/arm/arm,scmi.txt
+++ b/Documentation/devicetree/bindings/arm/arm,scmi.txt
@@ -102,7 +102,7 @@ Required sub-node properties:
[0] http://infocenter.arm.com/help/topic/com.arm.doc.den0056a/index.html
[1] Documentation/devicetree/bindings/clock/clock-bindings.txt
[2] Documentation/devicetree/bindings/power/power-domain.yaml
-[3] Documentation/devicetree/bindings/thermal/thermal.txt
+[3] Documentation/devicetree/bindings/thermal/thermal*.yaml
[4] Documentation/devicetree/bindings/sram/sram.yaml
[5] Documentation/devicetree/bindings/reset/reset.txt
diff --git a/Documentation/devicetree/bindings/arm/arm,scpi.txt b/Documentation/devicetree/bindings/arm/arm,scpi.txt
index dd04d9d9a1b8..bcd6c3ec471e 100644
--- a/Documentation/devicetree/bindings/arm/arm,scpi.txt
+++ b/Documentation/devicetree/bindings/arm/arm,scpi.txt
@@ -108,7 +108,7 @@ Required properties:
[0] http://infocenter.arm.com/help/topic/com.arm.doc.dui0922b/index.html
[1] Documentation/devicetree/bindings/clock/clock-bindings.txt
-[2] Documentation/devicetree/bindings/thermal/thermal.txt
+[2] Documentation/devicetree/bindings/thermal/thermal*.yaml
[3] Documentation/devicetree/bindings/sram/sram.yaml
[4] Documentation/devicetree/bindings/power/power-domain.yaml
diff --git a/Documentation/devicetree/bindings/arm/freescale/fsl,scu.txt b/Documentation/devicetree/bindings/arm/freescale/fsl,scu.txt
index 10b8459e49f8..6064d98b1031 100644
--- a/Documentation/devicetree/bindings/arm/freescale/fsl,scu.txt
+++ b/Documentation/devicetree/bindings/arm/freescale/fsl,scu.txt
@@ -176,7 +176,7 @@ Required properties:
"fsl,imx8qxp-sc-thermal"
followed by "fsl,imx-sc-thermal";
-- #thermal-sensor-cells: See Documentation/devicetree/bindings/thermal/thermal.txt
+- #thermal-sensor-cells: See Documentation/devicetree/bindings/thermal/thermal-sensor.yaml
for a description.
Example (imx8qxp):
diff --git a/Documentation/devicetree/bindings/arm/marvell/ap80x-system-controller.txt b/Documentation/devicetree/bindings/arm/marvell/ap80x-system-controller.txt
index 098d932fc963..e31511255d8e 100644
--- a/Documentation/devicetree/bindings/arm/marvell/ap80x-system-controller.txt
+++ b/Documentation/devicetree/bindings/arm/marvell/ap80x-system-controller.txt
@@ -111,7 +111,7 @@ Thermal:
--------
For common binding part and usage, refer to
-Documentation/devicetree/bindings/thermal/thermal.txt
+Documentation/devicetree/bindings/thermal/thermal*.yaml
The thermal IP can probe the temperature all around the processor. It
may feature several channels, each of them wired to one sensor.
diff --git a/Documentation/devicetree/bindings/arm/marvell/cp110-system-controller.txt b/Documentation/devicetree/bindings/arm/marvell/cp110-system-controller.txt
index f982a8ed9396..a21f7709596c 100644
--- a/Documentation/devicetree/bindings/arm/marvell/cp110-system-controller.txt
+++ b/Documentation/devicetree/bindings/arm/marvell/cp110-system-controller.txt
@@ -203,7 +203,7 @@ It is possible to setup an overheat interrupt by giving at least one
critical point to any subnode of the thermal-zone node.
For common binding part and usage, refer to
-Documentation/devicetree/bindings/thermal/thermal.txt
+Documentation/devicetree/bindings/thermal/thermal*.yaml
Required properties:
- compatible: must be one of:
diff --git a/Documentation/devicetree/bindings/cpufreq/cpufreq-dt.txt b/Documentation/devicetree/bindings/cpufreq/cpufreq-dt.txt
index 332aed8f4597..56f442374383 100644
--- a/Documentation/devicetree/bindings/cpufreq/cpufreq-dt.txt
+++ b/Documentation/devicetree/bindings/cpufreq/cpufreq-dt.txt
@@ -18,7 +18,8 @@ Optional properties:
in unit of nanoseconds.
- voltage-tolerance: Specify the CPU voltage tolerance in percentage.
- #cooling-cells:
- Please refer to Documentation/devicetree/bindings/thermal/thermal.txt.
+ Please refer to
+ Documentation/devicetree/bindings/thermal/thermal-cooling-devices.yaml.
Examples:
diff --git a/Documentation/devicetree/bindings/cpufreq/cpufreq-mediatek.txt b/Documentation/devicetree/bindings/cpufreq/cpufreq-mediatek.txt
index 0551c78619de..ea4994b35207 100644
--- a/Documentation/devicetree/bindings/cpufreq/cpufreq-mediatek.txt
+++ b/Documentation/devicetree/bindings/cpufreq/cpufreq-mediatek.txt
@@ -21,8 +21,8 @@ Optional properties:
flow is handled by hardware, hence no software "voltage tracking" is
needed.
- #cooling-cells:
- Please refer to Documentation/devicetree/bindings/thermal/thermal.txt
- for detail.
+ For details, please refer to
+ Documentation/devicetree/bindings/thermal/thermal-cooling-devices.yaml
Example 1 (MT7623 SoC):
diff --git a/Documentation/devicetree/bindings/cpufreq/nvidia,tegra20-cpufreq.txt b/Documentation/devicetree/bindings/cpufreq/nvidia,tegra20-cpufreq.txt
index daeca6ae6b76..52a24b82fd86 100644
--- a/Documentation/devicetree/bindings/cpufreq/nvidia,tegra20-cpufreq.txt
+++ b/Documentation/devicetree/bindings/cpufreq/nvidia,tegra20-cpufreq.txt
@@ -5,7 +5,7 @@ Required properties:
- clocks: Must contain an entry for the CPU clock.
See ../clocks/clock-bindings.txt for details.
- operating-points-v2: See ../bindings/opp/opp.txt for details.
-- #cooling-cells: Should be 2. See ../thermal/thermal.txt for details.
+- #cooling-cells: Should be 2. See ../thermal/thermal-cooling-devices.yaml for details.
For each opp entry in 'operating-points-v2' table:
- opp-supported-hw: Two bitfields indicating:
diff --git a/Documentation/devicetree/bindings/hwmon/gpio-fan.txt b/Documentation/devicetree/bindings/hwmon/gpio-fan.txt
index 2becdcfdc840..f4cfa350f6a1 100644
--- a/Documentation/devicetree/bindings/hwmon/gpio-fan.txt
+++ b/Documentation/devicetree/bindings/hwmon/gpio-fan.txt
@@ -12,7 +12,8 @@ Optional properties:
- alarm-gpios: This pin going active indicates something is wrong with
the fan, and a udev event will be fired.
- #cooling-cells: If used as a cooling device, must be <2>
- Also see: Documentation/devicetree/bindings/thermal/thermal.txt
+ Also see:
+ Documentation/devicetree/bindings/thermal/thermal-cooling-devices.yaml
min and max states are derived from the speed-map of the fan.
Note: At least one the "gpios" or "alarm-gpios" properties must be set.
diff --git a/Documentation/devicetree/bindings/hwmon/lm90.txt b/Documentation/devicetree/bindings/hwmon/lm90.txt
index c76a7ac47c34..398dcb965751 100644
--- a/Documentation/devicetree/bindings/hwmon/lm90.txt
+++ b/Documentation/devicetree/bindings/hwmon/lm90.txt
@@ -34,8 +34,8 @@ Optional properties:
LM90 "-ALERT" pin output.
See interrupt-controller/interrupts.txt for the format.
-- #thermal-sensor-cells: should be set to 1. See thermal/thermal.txt for
- details. See <include/dt-bindings/thermal/lm90.h> for the
+- #thermal-sensor-cells: should be set to 1. See thermal/thermal-sensor.yaml
+ for details. See <include/dt-bindings/thermal/lm90.h> for the
definition of the local, remote and 2nd remote sensor index
constants.
diff --git a/Documentation/devicetree/bindings/thermal/allwinner,sun8i-a83t-ths.yaml b/Documentation/devicetree/bindings/thermal/allwinner,sun8i-a83t-ths.yaml
index 87369264feb9..44ba6765697d 100644
--- a/Documentation/devicetree/bindings/thermal/allwinner,sun8i-a83t-ths.yaml
+++ b/Documentation/devicetree/bindings/thermal/allwinner,sun8i-a83t-ths.yaml
@@ -50,7 +50,7 @@ properties:
nvmem-cell-names:
const: calibration
- # See ./thermal.txt for details
+ # See Documentation/devicetree/bindings/thermal/thermal-sensor.yaml for details
"#thermal-sensor-cells":
enum:
- 0
diff --git a/Documentation/devicetree/bindings/thermal/amazon,al-thermal.txt b/Documentation/devicetree/bindings/thermal/amazon,al-thermal.txt
index 703979dbd577..12fc4ef04837 100644
--- a/Documentation/devicetree/bindings/thermal/amazon,al-thermal.txt
+++ b/Documentation/devicetree/bindings/thermal/amazon,al-thermal.txt
@@ -6,7 +6,7 @@ transaction.
Required properties:
- compatible: "amazon,al-thermal".
- reg: The physical base address and length of the sensor's registers.
-- #thermal-sensor-cells: Must be 1. See ./thermal.txt for a description.
+- #thermal-sensor-cells: Must be 1. See Documentation/devicetree/bindings/thermal/thermal-sensor.yaml for a description.
Example:
thermal: thermal {
diff --git a/Documentation/devicetree/bindings/thermal/brcm,avs-ro-thermal.yaml b/Documentation/devicetree/bindings/thermal/brcm,avs-ro-thermal.yaml
index f3e68ed03abf..1ab5070c751d 100644
--- a/Documentation/devicetree/bindings/thermal/brcm,avs-ro-thermal.yaml
+++ b/Documentation/devicetree/bindings/thermal/brcm,avs-ro-thermal.yaml
@@ -23,7 +23,7 @@ properties:
compatible:
const: brcm,bcm2711-thermal
- # See ./thermal.txt for details
+ # See Documentation/devicetree/bindings/thermal/thermal-sensor.yaml for details
"#thermal-sensor-cells":
const: 0
diff --git a/Documentation/devicetree/bindings/thermal/brcm,bcm2835-thermal.txt b/Documentation/devicetree/bindings/thermal/brcm,bcm2835-thermal.txt
index da8c5b73ad10..a3e9ec5dc7ac 100644
--- a/Documentation/devicetree/bindings/thermal/brcm,bcm2835-thermal.txt
+++ b/Documentation/devicetree/bindings/thermal/brcm,bcm2835-thermal.txt
@@ -7,7 +7,7 @@ compatible: should be one of: "brcm,bcm2835-thermal",
"brcm,bcm2836-thermal" or "brcm,bcm2837-thermal"
reg: Address range of the thermal registers.
clocks: Phandle of the clock used by the thermal sensor.
-#thermal-sensor-cells: should be 0 (see thermal.txt)
+#thermal-sensor-cells: should be 0 (see Documentation/devicetree/bindings/thermal/thermal-sensor.yaml)
Example:
diff --git a/Documentation/devicetree/bindings/thermal/hisilicon-thermal.txt b/Documentation/devicetree/bindings/thermal/hisilicon-thermal.txt
index cef716a236f1..4b19d80e6558 100644
--- a/Documentation/devicetree/bindings/thermal/hisilicon-thermal.txt
+++ b/Documentation/devicetree/bindings/thermal/hisilicon-thermal.txt
@@ -9,7 +9,7 @@
by /SOCTHERM/tsensor.
- clock-names: Input clock name, should be 'thermal_clk'.
- clocks: phandles for clock specified in "clock-names" property.
-- #thermal-sensor-cells: Should be 1. See ./thermal.txt for a description.
+- #thermal-sensor-cells: Should be 1. See Documentation/devicetree/bindings/thermal/thermal-sensor.yaml for a description.
Example :
diff --git a/Documentation/devicetree/bindings/thermal/max77620_thermal.txt b/Documentation/devicetree/bindings/thermal/max77620_thermal.txt
index 323a3b3822aa..82ed5d487966 100644
--- a/Documentation/devicetree/bindings/thermal/max77620_thermal.txt
+++ b/Documentation/devicetree/bindings/thermal/max77620_thermal.txt
@@ -8,12 +8,12 @@ below threshold level.
Required properties:
-------------------
-#thermal-sensor-cells: Please refer <devicetree/bindings/thermal/thermal.txt>
- for more details.
+#thermal-sensor-cells: For more details, please refer to
+ <devicetree/bindings/thermal/thermal-sensor.yaml>
The value must be 0.
For more details, please refer generic thermal DT binding document
-<devicetree/bindings/thermal/thermal.txt>.
+<devicetree/bindings/thermal/thermal*.yaml>.
Please refer <devicetree/bindings/mfd/max77620.txt> for mfd DT binding
document for the MAX77620.
diff --git a/Documentation/devicetree/bindings/thermal/mediatek-thermal.txt b/Documentation/devicetree/bindings/thermal/mediatek-thermal.txt
index f8d7831f3974..1e249c42fae0 100644
--- a/Documentation/devicetree/bindings/thermal/mediatek-thermal.txt
+++ b/Documentation/devicetree/bindings/thermal/mediatek-thermal.txt
@@ -23,7 +23,7 @@ Required properties:
- resets: Reference to the reset controller controlling the thermal controller.
- mediatek,auxadc: A phandle to the AUXADC which the thermal controller uses
- mediatek,apmixedsys: A phandle to the APMIXEDSYS controller.
-- #thermal-sensor-cells : Should be 0. See ./thermal.txt for a description.
+- #thermal-sensor-cells : Should be 0. See Documentation/devicetree/bindings/thermal/thermal-sensor.yaml for a description.
Optional properties:
- nvmem-cells: A phandle to the calibration data provided by a nvmem device. If
diff --git a/Documentation/devicetree/bindings/thermal/nvidia,tegra124-soctherm.txt b/Documentation/devicetree/bindings/thermal/nvidia,tegra124-soctherm.txt
index f02f38527a6b..db880e7ed713 100644
--- a/Documentation/devicetree/bindings/thermal/nvidia,tegra124-soctherm.txt
+++ b/Documentation/devicetree/bindings/thermal/nvidia,tegra124-soctherm.txt
@@ -28,9 +28,10 @@ Required properties :
See ../reset/reset.txt for details.
- reset-names : Must include the following entries:
- soctherm
-- #thermal-sensor-cells : Should be 1. See ./thermal.txt for a description
- of this property. See <dt-bindings/thermal/tegra124-soctherm.h> for a
- list of valid values when referring to thermal sensors.
+- #thermal-sensor-cells : Should be 1. For a description of this property, see
+ Documentation/devicetree/bindings/thermal/thermal-sensor.yaml.
+ See <dt-bindings/thermal/tegra124-soctherm.h> for a list of valid values
+ when referring to thermal sensors.
- throttle-cfgs: A sub-node which is a container of configuration for each
hardware throttle events. These events can be set as cooling devices.
* throttle events: Sub-nodes must be named as "light" or "heavy".
@@ -62,7 +63,8 @@ Required properties :
TEGRA_SOCTHERM_THROT_LEVEL_MED (75%),
TEGRA_SOCTHERM_THROT_LEVEL_HIGH (85%).
- #cooling-cells: Should be 1. This cooling device only support on/off state.
- See ./thermal.txt for a description of this property.
+ For a description of this property see:
+ Documentation/devicetree/bindings/thermal/thermal-cooling-devices.yaml
Optional properties: The following properties are T210 specific and
valid only for OCx throttle events.
diff --git a/Documentation/devicetree/bindings/thermal/nvidia,tegra186-bpmp-thermal.txt b/Documentation/devicetree/bindings/thermal/nvidia,tegra186-bpmp-thermal.txt
index e17c07be270b..fc87f6aa1b8f 100644
--- a/Documentation/devicetree/bindings/thermal/nvidia,tegra186-bpmp-thermal.txt
+++ b/Documentation/devicetree/bindings/thermal/nvidia,tegra186-bpmp-thermal.txt
@@ -8,7 +8,7 @@ exposed by BPMP.
The BPMP thermal node must be located directly inside the main BPMP node. See
../firmware/nvidia,tegra186-bpmp.txt for details of the BPMP binding.
-This node represents a thermal sensor. See thermal.txt for details of the
+This node represents a thermal sensor. See Documentation/devicetree/bindings/thermal/thermal-sensor.yaml for details of the
core thermal binding.
Required properties:
diff --git a/Documentation/devicetree/bindings/thermal/qcom-spmi-temp-alarm.txt b/Documentation/devicetree/bindings/thermal/qcom-spmi-temp-alarm.txt
index 0273a92a2a84..2d5b2ad03314 100644
--- a/Documentation/devicetree/bindings/thermal/qcom-spmi-temp-alarm.txt
+++ b/Documentation/devicetree/bindings/thermal/qcom-spmi-temp-alarm.txt
@@ -8,7 +8,7 @@ Required properties:
- compatible: Should contain "qcom,spmi-temp-alarm".
- reg: Specifies the SPMI address.
- interrupts: PMIC temperature alarm interrupt.
-- #thermal-sensor-cells: Should be 0. See thermal.txt for a description.
+- #thermal-sensor-cells: Should be 0. See Documentation/devicetree/bindings/thermal/thermal-sensor.yaml for a description.
Optional properties: